Golden Oak Designer See-Thru
The traditional beauty of Golden Oak Designer or Split Oak See-Thru logs add to the elegant burn of the G9 Vent-Free Burner System. Dancing flames and an ember bed, featuring an innovative reflective panel, offer comforting heat and fireside charm. Lava granules and Bryte Coals included with this unit.
In Front of The Fireplace:
Be certain that combustible flooring material (i.e.: carpet, tile, etc) is not too close to the vent-free unit. If the vent-free burner system is at floor level or less than 6" above the floor, there MUST be at least 12" of noncombustible material between the front of the fireplace and any combustible flooring.
This burner system is equipped with an Oxygen Depletion Sensor (ODS) safety pilot system. The ODS senses the amount of oxygen available in the room and shuts the burner system off before the oxygen level drops below 18%. The pilot can only be relit when fresh air is available. This may require opening a window or door to another room or cracking the damper open slightly.
IMPORTANT Information: We highly recommend that this log set be purchased with an associated burner from this site. Logs are designed and manufactured to work with the burners listed. We do not warrant any log set if not purchased with a burner system as indicated on this site. As always, please call us with questions at 866-238-9228
Log Set Sizes
|
Min. Fireplace Width
|
Min. Depth
|
Min. Height
|
BTU Rating
|
12"
|
15" Front & 12" Rear
|
11"
|
17"
|
25,000 (NG & LP)
|
16/19"
|
22" Front & 17" Rear
|
11"
|
17"
|
39,000 (NG & LP)
|
18/20"
|
24" Front & 20" Rear
|
13"
|
17"
|
75,000 (NG) & 50,000 (LP)
|
24"
|
28" Front & 24" Rear
|
13"
|
17"
|
90,000 (NG) & 65,000 (LP)
|
30"
|
34" Front & 30" Rear
|
14"
|
17"
|
90,000 (NG) & 65,000 (LP)
|
36"
|
40" Front & 36" Rear
|
16"
|
17"
|
120,000 (NG) & 90,000 (LP)
|
42"
|
46" Front & 42" Rear
|
20"
|
17"
|
130,000 (NG) & 110,000 (LP)
|
48"
|
54" Front & 48" Rear
|
20"
|
17"
|
145,000 (NG) & 115,000 (LP)
|
60"
|
66" Front & 60" Rear
|
20"
|
17"
|
150,000 (NG) & 120,000 (LP)
|
Log Set Sizes
|
Min. Fireplace Width
|
Min. Depth
|
Min. Height
|
BTU Rating
|
12"
|
19" Front & 13" Rear
|
11"
|
17"
|
25,000 (NG & LP)
|
16/19"
|
25" Front & 20" Rear
|
11"
|
17"
|
39,000 (NG & LP)
|
18/20"
|
30" Front & 24" Rear
|
13"
|
17"
|
75,000 (NG) & 50,000 (LP)
|
24"
|
34" Front & 28" Rear
|
13"
|
17"
|
90,000 (NG) & 65,000 (LP)
|
30"
|
40" Front & 34" Rear
|
14"
|
17"
|
90,000 (NG) & 65,000 (LP)
|
36"
|
46" Front & 40" Rear
|
16"
|
17"
|
120,000 (NG) & 90,000 (LP)
|
42"
|
52" Front & 46" Rear
|
20"
|
17"
|
130,000 (NG) & 110,000 (LP)
|
48"
|
60" Front & 50" Rear
|
20"
|
17"
|
145,000 (NG) & 115,000 (LP)
|
60"
|
72" Front & 62" Rear
|
20"
|
17"
|
150,000 (NG) & 120,000 (LP)
|
Add 2" to front and rear width for any other auto-pilot kits
Log Set Sizes
|
Min. Fireplace Width
|
Min. Depth
|
Min. Height
|
BTU Rating
|
16/19"
|
29" Front & 22" Rear
|
11"
|
17"
|
40,000 (NG) & 30,000 (LP)
|
18/20"
|
30" Front & 24" Rear
|
13"
|
17"
|
70,000 (NG) & 45,000 (LP)
|
24"
|
34" Front & 28" Rear
|
13"
|
17"
|
90,000 (NG) & 65,000 (LP)
|
30"
|
40" Front & 34" Rear
|
16"
|
17"
|
95,000 (NG) & 75,000 (LP)
|
36"
|
46" Front & 40" Rear
|
16"
|
17"
|
95,000 (NG) & 75,000 (LP)
|
Add 2" to front and rear width for 01 & 02 Models
Log Set Sizes
|
Min. Fireplace Width
|
Min. Depth
|
Min. Height
|
BTU Rating
|
18/20"
|
26" Front & 20" Rear
|
15"
|
17"
|
40,000 (NG & LP)
|
24"
|
30" Front & 24" Rear
|
15"
|
17"
|
55,000 (NG & LP)
|
30"
|
36" Front & 28" Rear
|
15"
|
17"
|
65,000 (NG & LP)
|
Add 2" to front and rear width for 01 & 02 Models
Log Set Sizes
|
Min. Fireplace Width
|
Min. Depth
|
Min. Height
|
BTU Rating
|
18/20"
|
25" Front & 20" Rear
|
15"
|
17"
|
55K/20K^ (NG) & 40K/21K^ (LP)
|
24"
|
35" Front & 25" Rear
|
15"
|
17"
|
65K/21K^ (NG) & 50K/22K^ (LP)
|
30"
|
39" Front & 28" Rear
|
15"
|
17"
|
65K/21K^ (NG) & 50K/22K^ (LP)
|
Add 2" to front and rear width for 02 Models
^ 2VT Models Only
IMPORTANT Information:
We highly recommend that this log set be purchased with an associated burner from this site. Logs are designed and manufactured to work with the burners listed. We do not warrant any log set if not purchased with a burner system as indicated on this site. As always, please call us with questions at 866-238-12042
Ventless Gas Log BTU Calculator!
Ventless gas logs MUST NOT exceed a certain BTU rating based on the size of a room. The formula for calculating the maximum BTU allowed is: Room Width x Room Length x Ceiling Height x 20. You can use this tool below to perform the calculation.
Enter your ROOM DIMENSIONS:
Important Note: Professional Installation is required for all ventless products. Vent Free gas logs are not recommended for use in elevations over 2,000 feet. We advise that you install a high quality Carbon Monoxide Detector if you install a ventless gas log. Some cities do not allow vent free gas logs to be installed in bedrooms, bathrooms or other confined spaces, others do not allow ventless gas logs to be installed at all (California for example). Check local building codes for any restrictions or conditions regarding ventless logs before you purchase or install them.
|
|
 |